4.4
Setting of Network Configuration
4-19
4.4.5 Restarting Power Supplies and Checking Communication State
Download the parameters set by CMI to FP7 MC Unit, and then restart the power supplies for
the system (Unit and Servo Amplifier). The setting is reflected and the communication is
started.
PROCEDURE
1. Turn off the power supplies of FP7 MC Unit and Servo Amplifier A6B/A5B.
2. Turn on the power supply of Servo Amplifier A6B/A5B.
3. Turn on the power supply of FP7 MC Unit.
EtherCAT communication is started between Servo Amplifier A6B/A5B and FP7
MC Unit. Once the communication is executed and the link is established properly,
the both "EC RUN" LEDs turn on.
4. Confirm that no error occurs.
When an error occurs, the ERR LED on FP7 MC Unit turns on.
KEY POINTS
•
The connection state of the network can be checked by monitoring the unit
memories. The information on abnormal slaves is stored in the unit
memories (UM 0012E to UM 00139).
•
When the configuration is different from the network configuration set by
CMI, an error occurs.
•
The participation wait time for the nodes (slaves) connected to the
EtherCAT network can be set in the "MC common settings" menu of CMI
after the power-on of FP7 MC Unit.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......