Troubleshooting
15-14
15.3.3 AMP Communication Errors (From 00F0 2000H)
These are the errors occurred in the communication between FP7 MC Unit and AMP. They
occur when the communication data was judged as abnormal.
●
:
Recoverable, -: Unrecoverable
Error
code
Error name
Description
Object
Recovered
Countermeasures
2020H
AMP station
address
duplicate error
The AMPs with the same
station address exist in the
network.
All axes
-
After checking the station
address settings of AMP, turn off
the power supply and turn it on
again.
2030H
AMP station
address setting
error
The AMP with a station
address outside the
settable range exists.
All axes
-
2060H
No ENI file
No ENI file exists in FP7
MC Unit.
All axes
-
Download CMI project data.
2061H
Network
configuration
verify error
The network configuration
defined in the ENI file is
different from the actual
network configuration.
All axes
-
Check whether the configuration
matches the connection
configuration set on CMI.
2062H
Process data
receive timeout
error
The PDO (Process data)
communication error
occurred.
All axes
-
Check the communication cable
to see if it is correctly connected.
Check the power supply of
Servo Amplifier A6B/A5B.
2063H
SDO
communication
error
The SDO communication
error occurred.
Each
axis
- Check the setting parameters
for SDO communication.
- Check if there is anything
wrong with SDO communication
devices (slaves).
2064H
SDO
communication
timeout
The SDO communication
timeout occurred.
Each
axis
- Check if there is anything
wrong with communication
destination devices (slaves).
- Check the connection of LAN
cable.
2065H
PDO
communication
data size error
The PDO communication
data size error occurred.
All
axes/
Each
axis
- Data exceeded the maximum
data size for PDO
communication (5736 bytes).
- Data exceeded the maximum
data size for PDO
communication (1 node) (1
byte).
2070H
ESM change
error
ESM could not be changed.
All
axes/
Each
axis
Conditional
- Make the ESM change control
area setting correctly.
* There are both cases that the
error can be recovered and
cannot be recovered.
(Note 1): To simplify the displays, only the lower four digits (Hex) of each error code are displayed in the above table.
(Note 2): The power supply must be turned off and on again to recover the errors whose "Recovered" column is "-".
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......