8.9
Reconstruction of Positioning Data by User Programs
8-51
Positioning data setting area
Unit memory
no. (Hex)
Name
Default
Description
UM 06248
Control code
H0
Set the position setting mode and acceleration/deceleration pattern
for the positioning operation.
bit
Name
Description
0
Control method
0: Increment mode
1: Absolute mode
1
Acceleration/deceleration
method
0: Linear acceleration/deceleration
1: S-shaped
acceleration/deceleration
15-2
-
-
UM 06249
Operation
Patterns
H0
Set the single and interpolation operation pattern for the positioning
operation. The relation of the interpolation depends on the settings
in the axis group setting area in the common area of the unit
memory. In the interpolation operation, the setting for the axis with
the smallest number in an axis group is effective.
bit
Name
Description
7-0
Control
pattern
H00: E-point control (End point control)
H01: P-point control (Pass point control)
H02: C-point control (Continuance point
control)
H03: J-point control (Speed point control)
Any other settings will be errors.
15-8
Interpolation
setting
H00: Linear interpolation (Composite speed)
H01: Linear interpolation (Major axis speed)
H10: Circular interpolation (Center point/CW
direction)
H11: Circular interpolation (Center point/CCW
direction)
H20: Circular interpolation (Pass point):
H50: Spiral interpolation (Center point/CW
direction/1st axis feed)
H51: Spiral interpolation (Center point/CCW
direction/1st axis feed)
H52: Spiral interpolation (Center point/CW
direction/2nd axis feed)
H53: Spiral interpolation (Center point/CCW
direction/2nd axis feed)
H54: Spiral interpolation (Center point/CW
direction/3rd axis feed)
H55: Spiral interpolation (Center point/CCW
direction/3rd axis feed)
H60: Spiral interpolation (Pass point/1st axis
feed)
H61: Spiral interpolation (Pass point/2nd axis
feed)
H62: Spiral interpolation (Pass point/3rd axis
feed)
Any other settings will be errors.
UM 0624A
- UM 0624B
Reserved for
system
UM 0624C
Positioning
acceleration
time
U100
Set the acceleration and deceleration time for the positioning
operation.
Range: 0 to 10,000 (ms)
Any other settings will be errors. In the interpolation control, the
setting for the axis with the smallest number in an axis group is
effective.
UM 0624D
Positioning
deceleration
time
U100
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......