Supplementary
Functions
13-6
Home coordinates area (Unit memories)
Axis
no.
Unit
memory
no. (Hex)
Name
Default Description
Axis 1
UM 0328E
- UM 0328F
Home
coordinates
K0
Set the home coordinates to be set after the completion of the
home return.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as below.
pulse: -2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm):
-
214,748,364.8 to 214,748,364.7 μm
μm (1 μm):
-
2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -21,474.83648 to 21,474.83647 inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647 inches
degree (0.1 degree): -214,748,364.8 to 214,748,364.7 degrees
degree (1 degree): -2,147,483,648 to 2,147,483,647 degrees
An integer equivalent to the current value after unit conversion is
set to the unit memory.
Example) When the unit is μm (0.1 μm), set to "10000" for making
it be 1000.0 μm.
-
-
Axis 2
UM 0330E
- UM 0330F
-
-
Axis 64
UM 0520E
- UM 0520F
-
-
Virtual
axis 1
UM 0528E
- UM 0528F
-
-
Virtual
axis 32
UM 0620E
- UM 0620F
(Note 1): As for the unit memories in which the home coordinates are set, 2-word area is allocated for each axis.
(Note 2): The difference between the unit memory number of the target axis number and the unit memory number of
the adjacent axis number is H80 (for 128 words).
KEY POINTS
•
An integer equivalent to the current value after unit conversion is set for
home coordinates.
Example) When the unit is μm (0.1 μm), set to "10000" for making it be
1000.0 μm.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......