Automatic
Operation (Position Control)
8-50
The unit memories used for rewriting positioning data is as follows.
Buffer control area for positioning data
Unit memory
no. (Hex)
Name
Default
Description
UM 06240
Request flag
control
H0
Write data to this area for sending/receiving data of buffers for
positioning data. After the completion of the execution, it is
rewritten to H0 by FP7 MC Unit.
H0000: Not request
H0001: Request
Any other settings will be errors.
UM 06241
Request code
control
H0
Set the request code of data control of buffer for positioning data.
H0080: Read request
H0081: Write request
Any other settings will be errors.
UM 06242
Response code
control
H0
Stores the response code for the request of the buffer for
positioning data.
H0000: Complete
H0001: During processing
HFF00: Setting value error
UM 06243
Axis number
control
U1
Specify the axis number of positioning data to be transferred.
Range
Corresponding axis no.
1 to 64
Corresponds to the existing axes 1 to 64.
65 to 96
Corresponds to the virtual axes 1 to 32.
Any other settings will be errors.
UM 06244
Start table
number
U1
Specify the starting table number of positioning data to be
transferred.
Range: 1 to 1000
Any other settings will be errors.
UM 06245
Table size
U1
Specify the table size of positioning data to be transferred.
Range: 1 to 500
Any other settings will be errors.
UM 06246
Extended
positioning
table usage
setting
U0
Set whether to use the extended positioning table or not.
bit
Name
Description
15-0
Extended positioning table
usage setting
0: Not make the table setting
1: Make the table setting
Any other settings will be
errors.
* When using the extended positioning table;
table nos. 401 to 500 is used as extended table nos. 10,001 to
10,100.
UM 06247
Extended
positioning
table usage
setting
corresponding
axis no.
U0
Set transfer axis numbers of positioning data.
Range
Corresponding axis no.
1 to 64
Corresponds to the existing axes 1 to 64.
65 to 96
Corresponds to the virtual axes 1 to 32.
Any other settings will be errors.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......