6.4
Monitor Function of CMI
6-9
Monitoring item
Item
Description
Revision
Indicates the revision number of Servo Amplifier A6B/A5B.
Station address
Indicates the station address of Servo Amplifier A6B/A5B allocated to each axis.
Connection status
Indicates the connection status of each axis.
Not connected / During stop / During operation / Warning occurs / Error occurs
Servo ready
Indicates the servo ready status on the servo amplifier side.
Ready (Green): Indicates that the servo is ready.
Off (White): Indicates the servo is off.
Home position proximity
Indicates the status of the near home input (HOME).
Near home (Green): Indicates the input is valid.
Off (White): Indicates the input is invalid.
Limit +
Indicates the status of the limit input. Monitored signals vary according to the settings
of "Axis parameter settings" of FP7 MC Unit.
Limit + (Green) or limit - (Green): Indicates the input is enabled.
Off (White): Indicates the input is disabled.
Limit -
FROM write count
Indicates the number of times of writing to FROM in FP7 MC Unit. Writing can be
performed up to 10000 times.
Firmware version
Indicates the firmware version of FP7 MC Unit.
Hardware version
Indicates the hardware version of FP7 MC Unit.
KEY POINTS
•
The input logics of the near home, limit + and limit - depend on the settings
of Servo Amplifier A6B/A5B and FP7 MC Unit.
•
The target limit inputs to be monitored vary according to the settings of axis
parameters as below. Confirm them with CMI.
Parameter
name
Selection
Description
Axis parameters
- Basic setup
- Limit switch
N: Disabled
Indicates the POT/NOT status of Servo Amplifier A6B/A5B.
Limit +: POT (CW over-travel inhibit input)
Limit -: NOT (CCW over-travel inhibit input)
A: Enabled
Indicates the SI-MON3/SI-MON4 status of Servo Amplifier
A6B/A5B.
Limit +: SI-MON3 (General-purpose monitor input 3)
Limit -: SI-MON4 (General-purpose monitor input 4)
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......