![background image](http://html1.mh-extra.com/html/omron/r88d-kn01h-ect-l/r88d-kn01h-ect-l_user-manual_744172233.webp)
7 - 7
7 Applied Functions
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
7
-1 Seq
u
en
ce I/O S
ignal
s
7
7-1
-2 Output Signals
Precautions for Correct Use
Precautions for Correct Use
•
Do not use any settings other than the settings listed.
•
You can allocate the same function to more than one output signal, but the set value must be
in the same logic.
•
When you disable the control output pin, the output transistor always stays OFF. It also does
not affect the response in EtherCAT Communications.
•
If you use the Brake Interlock Output (BKIR), you must set the function in all control modes.
Otherwise, an Interface Output Function Number Error 1 (Error No. 33.4) or an Interface
Output Function Number Error 2 (Error No. 33.5) will occur.
•
The Brake Interlock Output (BKIR) can be set only to NO (normally open) contacts. If set to NC
(normally close) contacts, an Interface Output Function Number Error 1 (Error No. 33.4) or an
Interface Output Function Number Error 2 (Error No. 33.5) will occur.
Remote Output 1
R-OUT1
10 hex
Setting not available
Remote Output 2
R-OUT2
11 hex
Setting not available
Magnetic Pole Position Estimation Completion Output
CS-CMP
12 hex
Setting not available
Signal name
Symbol
Set value
NO
NC