![Omron R88D-KN01H-ECT-L User Manual Download Page 394](http://html1.mh-extra.com/html/omron/r88d-kn01h-ect-l/r88d-kn01h-ect-l_user-manual_744172394.webp)
11 Adjustment Functions
11 - 20
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
4
Set the Damping Filter Selection (3213 hex).
Damping filters 1 to 4 can be switched according to the conditions of the machine vibration.
*1
The set value 1 and 2 are reserved for system use. Users are not allowed to set 1 and 2 for this
object.
*2
The table below shows the damping filter you can switch to based on the command direction.
(
3
: Enabled/–: Disabled)
Set value
Description
0
Up to two filters, Damping Filter 1 and Damping Filter 2, can be
used simultaneously.
1
Reserved
*1
2
Reserved
*1
3
The damping filters are switched in the direction of the position
command.
*2
Direction of
position command
Damping
filter 1
Damping
filter 2
Damping
filter 3
Damping
filter 4
Positive
3
–
3
–
Negative
–
3
–
3