Appendices
A - 142
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event name
Interface Output Function Number Error 2
Event code
384A 0000 hex
Description
There is an undefined number specification in the output signal (OUTM2) function allocation.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
–
–
–
System
-defined
variables
Variable
Data type
Name
None
–
–
Cause and
correction
Assumed cause
Correction
Prevention
There is an undefined number
specification in the output signal
(OUTM2) function allocation.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Attached
information
None
Precautions/
Remarks
“33” is displayed on the Servo Drive front panel and F533 is given as the AlarmCode (4001 hex).