![Omron R88D-KN01H-ECT-L User Manual Download Page 488](http://html1.mh-extra.com/html/omron/r88d-kn01h-ect-l/r88d-kn01h-ect-l_user-manual_744172488.webp)
Appendices
A - 42
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
•
This is the mapping for an application that uses different modes of operation.
•
Touch probe status is available.
•
Following Error Actual Value (60F4 hex) is provided.
1B03 hex
260th transmit PDO Mapping
Sub-index 00 hex
Number of objects in this PDO
Setting
range
–
Unit
–
Default
setting
0A hex
Data
attribute
–
Size
1 byte (U8)
Access
RO
PDO map
Not possible
Sub-index 01 hex
PDO entry 1 (1st Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
603F 0010 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 02 hex
PDO entry 2 (2nd Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
6041 0010 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 03 hex
PDO entry 3 (3rd Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
6064 0020 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 04 hex
PDO entry 4 (4th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
6077 0010 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 05 hex
PDO entry 5 (5th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
60F4 0020 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 06 hex
PDO entry 6 (6th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
6061 0008 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 07 hex
PDO entry 7 (7th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
60B9 0010 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 08 hex
PDO entry 8 (8th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
60BA 0020 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 09 hex
PDO entry 9 (9th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
60BC 0020 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 10 hex
PDO entry 10 (10th Input Object to be mapped)
Setting
range
–
Unit
–
Default
setting
60FD 0020 hex
Data
attribute
–
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
A l l