M451
May. 4, 2018
Page
529
of
1006
Rev.2.08
M4
51
S
E
RI
E
S
T
E
CH
NICA
L RE
F
E
R
E
NC
E
M
A
NU
A
L
PWM Rising Capture Data Register 0~5 (PWM_RCAPDAT 0~5)
Register
Offset
R/W
Description
Reset Value
PWM_RCAPD
AT0
0x20C R
PWM Rising Capture Data Register 0
0x0000_0000
PWM_RCAPD
AT1
0x214 R
PWM Rising Capture Data Register 1
0x0000_0000
PWM_RCAPD
AT2
0x21C R
PWM Rising Capture Data Register 2
0x0000_0000
PWM_RCAPD
AT3
0x224 R
PWM Rising Capture Data Register 3
0x0000_0000
PWM_RCAPD
AT4
0x22C R
PWM Rising Capture Data Register 4
0x0000_0000
PWM_RCAPD
AT5
0x234 R
PWM Rising Capture Data Register 5
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
RCAPDAT
7
6
5
4
3
2
1
0
RCAPDAT
Bits
Description
[31:16]
Reserved
Reserved.
[15:0]
RCAPDAT
PWM Rising Capture Data Register (Read Only)
When rising capture condition happened, the PWM counter value will be saved in
this register.