14 - 51
14. OPTIONS AND AUXILIARY EQUIPMENT
14.11 Power factor improving DC reactor
POINT
For 100VAC class servo amplifiers, the power factor improving DC reactor
cannot be used.
The power factor improving DC reactor increases the form factor of the servo amplifier's input current to
improve the power factor. It can decrease the power supply capacity. As compared to the power factor
improving AC reactor (FR-BAL), it can decrease the loss. The input power factor is improved to about 95%.
It is also effective to reduce the input side harmonics.
When connecting the power factor improving DC reactor to the servo amplifier, always disconnect the wiring
across P
1
-P
2
(For 11kW or more, disconnect the wiring across P-P
1
). If it remains connected, the effect of the
power factor improving DC reactor is not produced.
When used, the power factor improving DC reactor generates heat. To release heat, therefore, leave a 10cm
or more clearance at each of the top and bottom, and a 5cm or more clearance on each side.
[Unit: mm]
L
F
D
H
B or less
E
A or less
Terminal block - screw size G
2-F L notch
C or
les
s
Name plate
Mounting leg
Servo Amplifier
P
1
P
2
(Note1)
FR-BEL
5m or less
(Note2)
Note 1. When using the power factor improving DC reactor, disconnect the wiring across P-P
1
.
2. For 11kW or more, the wiring across P-P
1
is connected.
Dimensions [mm]
Servo Amplifier
Power Factor
Improving DC
Reactor
A B C D E F L G H
Mounting
Screw
Size
Mass
[kg(lb)]
Used Power
Supply
[mm
2
]
MR-J3-10T
20T
FR-BEL-0.4K
110 50 94 1.6 95 6 12
M3.5
25 M5 0.5
(1.10)
MR-J3-40T FR-BEL-0.75K
120 53 102 1.6 105 6 12 M4 25 M5 0.7
(1.54)
MR-J3-60T
70T
FR-BEL-1.5K 130 65 110 1.6 115 6 12 M4 30 M5 1.1
(2.43)
MR-J3-100T FR-BEL-2.2K 130 65 110 1.6 115 6 12 M4 30 M5 1.2
(2.43)
2
(AWG14)
MR-J3-200T FR-BEL-3.7K 150 75 102 2.0 135 6 12 M4 40 M5 1.7
(3.75)
3.5
(AWG12)
MR-J3-350T FR-BEL-7.5K 150 75 126 2.0 135 6 12 M5 40 M5 2.3
(5.07)
5.5
(AWG10)
MR-J3-500T FR-BEL-11K 170 93 132 2.3 155 6 14 M5 50 M5 3.1
(6.84)
5.5(AWG10)
MR-J3-700T FR-BEL-15K 170 93 170 2.3 155 6 14 M8 56 M5 3.8
(8.38)
8(AWG8)
MR-J3-11KT FR-BEL-15K 170 93 170 2.3 155 6 14 M8 56 M5 3.8
(8.38)
22(AWG4)
MR-J3-15KT FR-BEL-22K 185 119 182 2.6 165 7 15 M8 70 M6 5.4
(11.91)
30(AWG2)
MR-J3-22KT FR-BEL-30K 185 119 201 2.6 165 7 15 M8 70 M6 6.7
(14.77) 60(AWG1/0)