4 - 24
4. SIGNALS AND WIRING
4.6.2 Movement finish rough match in position
POINT
If an alarm cause, etc. are removed and servo-on occurs after a stop is made
by servo-off, alarm occurrence or Forced stop (EMG) ON during automatic
operation, Movement finish (MEND), Rough-match, (CPO) and In position
(INP) are turned on. To resume operation, confirm the current position and
the selected point table No. for preventing unexpected operation.
(1) Movement finish
The following timing charts show the output timing relationships between the position command generated
in the servo amplifier and the movement finished (RYnC). This timing can be changed using parameter No.
PA10 (in-position range). RYnC turns ON in the servo-on status.
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Position command and
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
Movement finish (RXnC)
Forward
rotation
0r/min
When parameter No. PA10 is small
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Position command and
servo motor speed
Movement finish (RXnC)
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
Forward
rotation
0r/min
When parameter No. PA10 is large
Summary of Contents for MELSERVO MR-J3-xT
Page 22: ...8 MEMO ...
Page 156: ...4 46 4 SIGNALS AND WIRING MEMO ...
Page 276: ...7 26 7 MR Configurator MEMO ...
Page 324: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 418: ...14 66 14 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...