3 - 49
3. CC-LINK COMMUNICATION FUNCTIONS
3.7.6 Operation
This section explains the operation programs of the servo amplifier.
(1) JOG operation
Perform JOG operation of the servo amplifier of station 1 and read the "current position" data.
Code No.
Description
H0001
Lower 16-bit data of current position (hexadecimal)
H0002
Upper 16-bit data of current position (hexadecimal)
Servo-on command (RY00)
Forward rotation start (RY01)
Reverse rotation start (RY02)
Sets monitor code (H0001) of current
position (lower 16 bits) to RW
W0
.
Sets monitor code (H0002) of current
position (upper 16 bits) to RW
W1
.
Turns on monitor command (RY08).
Reads RW
R0
or RW
R1
to D120,
D121 of buffer memory when
Monitoring (RX08) turns on.
CIRCUIT END
Servo alarm
Forward rotation JOG command
Reverse rotation JOG command
Communication ready
Reads remote input (RX00 to RX1F)
of buffer memory to M200 to M231.
Writes M100 to M131 to remote output
(RY00 to RY1F) of buffer memory.