5 - 51
5. STARTUP
(2) Timing chart
0
0r/min
Forward rotation
Reverse rotation
Movement finish (RXnC)
Rough match (RXn2)
Home position return
completion (ZP)
Z-phase
Automatic/manual selection
(RYn6)
Servo motor speed
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Selected point table No.
ON
OFF
3ms or less
6ms or more
Creep speed
Home position return speed
Home position shift distance
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.