1 - 21
1. FUNCTIONS AND CONFIGURATION
1.7 Configuration including auxiliary equipment
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
(1) MR-J3-100T or less
(a) For 3-phase or 1-phase 200V to 230VAC
CN5
P
C
CN6
CN2
CN4
I/O signal
U
V
W
CN3
L
1
L
3
L
2
P
1
P
2
CN1
CC-Link
Magnetic
contactor
(MC)
(Note2)
Power factor
improving DC
reactor
(FR-BEL)
(Note2)
Regenerative option
(Note1)
Battery unit
MR-J3BAT
Servo motor
Personal
computer
MR Configurator
(Servo configuration
software)
Line noise
filter
(FR-BLF01)
Servo amplifier
R S T
(Note3)
3-phase or 1-phase
200V to 230VAC
power supply
No-fuse breaker
(NFB) or fuse
Note 1. The battery unit (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used.
3. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70T or less.
For 1-phase 200V to 230VAC, connect the power supply to L
1
L
2
and leave L
3
open.