14 - 52
14. OPTIONS AND AUXILIARY EQUIPMENT
14.12 Power factor improving reactors
The power factor improving reactors improve the phase factor by increasing the form factor of servo amplifier's
input current.
It can reduce the power capacity.
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be slightly
lower than 90%.
In addition, it reduces the higher harmonic of input side.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier.
If using only one power factor improving reactor, enough improvement effect of phase factor cannot be
obtained unless all servo amplifiers are operated.
Z
3-phase
200 to
230VAC
NFB
FR-BAL
Servo amplifier
MR-J3- T
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase
200v to 230VAC
NFB
FR-BAL
Servo amplifier
MR-J3- T
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
W
W1
C
RX S Y T Z
H
5
D1
Installation screw
D
5
[Unit : mm]
(Note)
1-phase
100 to120VAC
NFB
FR-BAL
Servo amplifier
MR-J3- T1
R
S
T
X
Y
L
1
Blank
MC
L
2
Note. For the 1-phase 200V to 230V power supply, Connect the power
supply to L1, L2 and leave L3 open.
Dimensions [mm]
Servo amplifier
Model
W W1 H D D1 C
Mounting
screw size
Terminal
screw
size
Mass
[kg (lb)]
MR-J3-10T/20T/10T1 FR-BAL-0.4K
135
120
115
59
45
-2.5
0
7.5 M4
M3.5
2.0
(4.4)
MR-J3-40T/20T1 FR-BAL-0.75K
135 120 115 69 57
-2.5
0
7.5 M4
M3.5
2.8
(6.17)
MR-J3-60T/70T/40T1 FR-BAL-1.5K
160
145
140
71
55
-2.5
0
7.5 M4
M3.5
3.7
(8.16)
MR-J3-100T FR-BAL-2.2K
160
145
140
91
75
-2.5
0
7.5 M4
M3.5
5.6
(12.35)
MR-J3-200T FR-BAL-3.7K
220
200
192
90
70 5 10 M5 M4
8.5
(18.74)
MR-J3-350T
FR-BAL-7.5K 220 200 194 120
100 5 10 M5 M5
14.5
(32.0)
MR-J3-500T
FR-BAL-11K 280 255 220 135 100 12.5 M6 M6
19
(41.9)
MR-J3-700T
295 270 275 133
MR-J3-11KT
FR-BAL-15K
295 270 275 133
110
0
-2.5
12.5 M6 M6
27(59.53)
MR-J3-15KT
FR-BAL-22K 290 240 301 199
170 5 25 M8 M8
35(77.16)
MR-J3-22KT
FR-BAL-30K 290 240 301 219