6 - 34
6. PARAMETERS
No. Symbol
Name and Function
Initial
value
Unit Setting
range
PD14 DIN3
External DI function selection 3
This function sets any signal imported from the CN6 connector.
part is for manufacturer setting. Do not set the value by any means.
8
Initial value
BIN
HEX
Signal name
0
0
0
1
BIN 0: Used in CC-Link
BIN 1: Used in CN6 external input signal
Proximity dog (DOG)
0
Initial value
BIN
HEX
Signal name
0
Automatic/manual
selection (MD0)
0
0
0
0
0
Initial value
BIN
HEX
Signal name
0
Temporary
stop/Restart (TSTP)
0
0
0
0800h Refer
to
Name and
function
column.
PD15
For manufacturer setting
Do not change this value by any means.
0000h
PD16 *DIAB Input polarity selection
Used to set the proximity dog input polarity. (Refer to section 5.6)
0
Proximity dog input polarity
0: OFF indicates detection of the dog.
1: ON indicates detection of the dog.
0
0
0000h Refer
to
Name and
function
column.
PD17
0000h
PD18
For manufacturer setting
Do not change this value by any means.
0000h
PD19 *DIF Response
level
setting
Used to select the input.
0 0 0
Input filter
If external input signal causes chattering due
to noise, etc., input filter is used to suppress it.
0: None
1: 0.88[ms]
2: 1.77[ms]
3: 2.66[ms]
4: 3.55[ms]
5: 4.44[ms]
0002h Refer
to
Name and
function
column.