3. CC-LINK COMMUNICATION FUNCTIONS
(3) Remote register-based point table No. setting (incremental value command system)
Operate the servo amplifier of station 2 with incremental values after specifying the point table No. 5 in the
direct specification mode.
Preset "
1" in parameter No. PA01 and "
2" in parameter No. PA30.
Set data
Description
K5
Point table No. (decimal)
Servo-on command (RY20)
Automatic operation selection (RY26)
Position command selection (RY4A)
Writes point table No. (K5) to RW
W8
.
Turns on position instruction demand (RY40).
Reads RW
R6
to D2 when position instruction
execution completion (RX40) turns on.
CIRCUIT END
Turns on forward rotation start command
(RY21).
Command request time 10ms
Turns off forward rotation start command
(RY21).
Turns off position instruction demand (RY40).
Incremental value selection (RY4B)
Operation
command
In position
Reads remote input (RX20 to RX5F) of buffer
memory to M200 to M263.
Writes M100 to M163 to remote output (RY20
to RY5F) of buffer memory.