5 - 49
5. STARTUP
(2) Timing chart
ON
OFF
0
Movement finish (RXnC)
Rough match (RXn2)
Home position return
completion (ZP)
Proximity dog (DOG)
Automatic/manual selection
(RYn6)
Servo motor speed
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Selected point table No.
Forward
rotation
0r/min
Reverse
rotation
3ms or less
6ms or more
Home position return speed
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Proximity dog
Moving distance after proximity dog
Home position shift distance
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.