3 - 10
3. CC-LINK COMMUNICATION FUNCTIONS
(2) When 2 stations are occupied
RXn/RYn: 64 points each, RWrn/RWwn: 8 points each
PLC
Servo amplifier (RYn)
Servo amplifier
PLC (RXn)
(Note 1)
Device No.
Signal name
Signal
abbreviation
CN6
connector
pin No.
(Note 1)
Device No.
Signal name
Signal
abbreviation
CN6
connector
pin No.
RYn0 Servo-on
SON
RXn0 Ready
RD
14
RYn1
Forward rotation start
ST1
RXn1
In position
INP
RYn2
Reverse rotation start
ST2
RXn2
Rough match
CPO
RYn3
Proximity dog
DOG
2
RXn3
Home position return completion
ZP
16
RYn4
Forward rotation stroke end
LSP
3
RXn4
Limiting torque
TLC
RYn5 Reverse
rotation
stroke
end
LSN
4
RXn5 Reserved
RYn6
Automatic/manual selection
MDO
RXn6
Electromagnetic brake interlock
MBR
RYn7
Temporary stop/Restart
TSTP
RXn7
Temporary stop
PUS
RYn8 Monitor
output
execution
demand MOR
RXn8 Monitoring
MOF
RYn9
Instruction code execution
demand
COR RXn9
Instruction code execution
completion
COF
RYnA
Point table No. selection 1
DI0
RXnA
Warning
WNG
RYnB
Point table No. selection 2
DI1
RXnB
Battery warning
BWNG
RYnC
Point table No. selection 3
DI2
RXnC
Movement finish
MEND
RYnD
Point table No. selection 4
DI3
RXnD
Dynamic brake interlock
DB
RYnE
Point table No. selection 5
DI4
RXnE
Position range output
POT
RYnF Clear
CR
RY(n+1)0
to
RY(n+1)9
Reserved
RXnF
to
RX(n+1)9
Reserved
RY(n+2)0
Position instruction execution
demand (Note)
RX(n+2)0
Position instruction execution
completion
RY(n+2)1
Speed instruction execution
demand (Note)
RX(n+2)1
Speed instruction execution
completion
RY(n+2)2
Reserved
RX(n+2)2
Point table No. output 1
PT0
RY(n+2)3
Point table No. selection 6
DI5
RX(n+2)3
Point table No. output 2
PT1
RY(n+2)4
Point table No. selection 7
DI6
RX(n+2)4
Point table No. output 3
PT2
RY(n+2)5
Point table No. selection 8
DI7
RX(n+2)5
Point table No. output 4
PT3
RY(n+2)6
Internal torque limit selection
TL1
RX(n+2)6
Point table No. output 5
PT4
RY(n+2)7
Proportion control
PC
RX(n+2)7
Point table No. output 6
PT5
RY(n+2)8
Gain switch
CDP
RX(n+2)8
Point table No. output 7
PT6
RY(n+2)9
Reserved
RX(n+2)9
Point table No. output 8
PT7
RY(n+2)A
Position/speed specifying system
selection
RX(n+2)A
to
RX(n+2)F
Reserved
RY(n+2)B
Absolute value/incremental value
selection
RX(n+3)0
to
RX(n+3)9
Reserved
RY(n+2)C
to
RY(n+2)F
Reserved
RX(n+3)A
Trouble ALM
15
RY(n+3)0
to
RY(n+3)9
Reserved
RX(n+3)B
Remote station communication
ready
CRD
RY(n+3)A Reset
RES
RX(n+3)C
to
RX(n+3)F
Reserved
RY(n+3)B
to
RY(n+3)F
Reserved
Note. "n" depends on the station number setting.