3 - 47
3. CC-LINK COMMUNICATION FUNCTIONS
(2) Writing the parameter
Change parameter No. PC12 (JOG speed) of the servo amplifier of station 2 to "100".
The parameter group PC is specified as follows.
Code No.
Description
8200h Parameter
group
selection
Set data
Description
K2
Set data (decimal)
The parameter No.12 is changed to "100" as follows.
Code No.
Description
H820C
Parameter No. PC12 write (hexadecimal)
Set data
Description
K100
Set data (decimal)
The answer code at instruction code execution is set to D2.
Reads remote input of buffer memory
(RX20 to RX5F) to M200 to M263.
Writes parameter group No. write
(H8200) to RW
W6
and parameter
group PC (K2) to RW
W7
.
Turns on instruction code execution
demand (RY29).
Turns off instruction code execution
demand (RY29) and proceeds to the
next when instruction code execution
completion (RX29) turns on.
Writes parameter No.PC12 write
(H820C) to RW
W6
and data (K100) to
RW
W7
.
Turns on instruction code execution demand
(RY29).
Reads RW
W6
to D2 when instruction code
execution completion (RX29) turns on.
Turn off instruction code execution demand
(RY29).
Writes M100 to M163 to remote output
(RY20 to RY5F) of buffer memory.