1 - 7
1. FUNCTIONS AND CONFIGURATION
1.2 Servo amplifier standard specifications
Servo Amplifier
MR-J3-
Item
10T 20T 40T 60T 70T 100T 200T 350T 500T 700T 11KT 15KT 22KT 10T1 20T1 40T1
Voltage/frequency
3-phase or 1-phase 200
to 230VAC, 50/60Hz
3-phase 200 to 230VAC, 50/60Hz
1-phase 100V to
120VAC, 50/60Hz
Permissible voltage fluctuation
3-phase or 1-phase 200
to 230VAC: 170 to
253VAC
3-phase 170 to 253VAC
1-phase 85 to
132VAC
Permissible frequency
fluctuation
Within 5%
Power supply capacity
Refer to section 13.2
P
ower s
uppl
y
Inrush current
Refer to section 13.5
Voltage,
frequency
1-phase 200 to 230VAC, 50/60Hz
1-phase 100 to
120VAC, 50/60Hz
Permissible
voltage
fluctuation
1-phase 170 to 253VAC
1-phase 85 to
132VAC
Permissible
frequency
fluctuation
Within 5%
Input 30W 45W
30W
Control circuit
power supply
Inrush current
Refer to section 13.5
Voltage,
frequency
DC24V 10%
Interface power
supply
Power supply
capacity
(Note 1) 150mA or more
Control System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
External option
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal relay),
servo motor overheat protection, encoder error protection, regenerative brake error protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Operational
specifications
Positioning by specifying the point table No. (255 points)
Position
command input
Set in point table. 1-point feed length setting range: 1[ m] to 999.999[mm]
Speed
command input
Set in point table. Acceleration/deceleration time is set in point table.
S-pattern acceleration/deceleration time constant is set in parameter No. PC13.
Point table
number
input
System
Signed absolute value command system, incremental value command system, signed absolute
value command/incremental value command specifying system
Operational
specifications
Remote register setting is used for positioning.
Position
command input
Remote register is used to set position command data.
Feed length input setting range: 1 m to 999.999m
Speed
command input
Remote register is used to make selection from point table.
Remote register is used to set speed command data (speed).
S-pattern acceleration/deceleration time constant is set in parameter No. PC13.
Com
m
and
syste
m
Position
command
data input
(when 2
stations are
occupied)
System
Signed absolute value command system, incremental value command system, signed absolute
value command/incremental value command specifying system
Point table
Point table number input, position data input system
Positioning operation is performed once in accordance with the position and speed commands.
Automatic
operation
mode
Automatic
continuous
operation
Varied speed operation (2 to 255 speeds), automatic continuous positioning operation (2 to 255
points)
Operat
ion m
ode
Manual
operation
mode
Jog
Jog operation is performed in accordance with the parameter-set speed command by contact input
or through CC-Link communication function.
Summary of Contents for MELSERVO MR-J3-xT