6 - 19
6. PARAMETERS
No. Symbol
Name and Function
Initial Value
Unit
Setting
Range
PB33 VRF1B Gain changing - vibration suppression control - vibration frequency setting
Set the vibration frequency for vibration suppression control when the gain
changing is valid. This parameter is made valid when the parameter No. PB02
setting is " 2" and the parameter No. PB26 setting is " 1".
When using the vibration suppression control gain changing, always execute
the changing after the servo motor has stopped.
100.0 Hz 0.1
to
100.0
PB34 VRF2B Gain changing - vibration suppression control - resonance frequency setting
Set the resonance frequency for vibration suppression control when the gain
changing is valid. This parameter is made valid when the parameter No. PB02
setting is " 2" and the parameter No. PB26 setting is " 1".
When using the vibration suppression control gain changing, always execute
the changing after the servo motor has stopped.
100.0 Hz 0.1
to
100.0
PB35
0.00
PB36
0.00
PB37
100
PB38
0
PB39
0
PB40
0
PB41
1125
PB42
1125
PB43
0004h
PB44
0.0
PB45
For manufacturer setting
Do not change this value by any means.
0000h