8 - 3
8. PARAMETER UNIT (MR-PRU03)
8.2 Specifications
Item Description
Model
MR-PRU03
Power supply
Supplied from the servo amplifier
Parameter mode
Basic setting parameters, Gain/filter parameters, Extension setting
parameters, I/O setting parameters
Monitor mode (Status display)
Current position, Command position, Command remaining distance, Point
table No., Feedback pulse value, Servo motor speed, Droop pulse value,
Regenerative load factor, Effective load factor, Peak load factor,
Instantaneous torque, Within one-revolution position, ABS counter, Load
inertia moment ratio, Bus voltage
Diagnosis mode
External I/O display, motor information
Alarm mode
Current alarm, Alarm history
Test operation mode
Jog operation, Positioning operation, DO forced output, Motor-less operation,
Single-step feed
F
unc
tion
s
Point table mode
Point data, Servo motor speed, Acceleration/deceleration time constant,
Dwell, Auxiliary function
Display section
LCD system (16 characters 4 lines)
Ambient temperature
10 to 55 (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
Storage temperature range
20 to 65 (non-freezing)
Storage humidity range
90%RH or less (non-condensing)
E
nv
ironm
en
t
Ambience
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist,
dust and dirt
Mass [g]
130
8.3 Outline dimension drawings
[Unit: mm]
72
15
10.5
48
13
24
40
5-M3 screw
5- 4 hole
40
Punched hole
16.5
11.75
23.75
1.25
Mounting hole dimension
Front face
Side face
Back face