15 - 41
15. COMMUNICATION FUNCTION
(e) Dwell
Read the dwell of the point table.
1) Transmission
Transmit command [6][0] and any of data No. [0][1] to [F][F] corresponding to the point table to be
read. Refer to section 15.4.1.
2) Reply
The slave station sends back the dwell of the requested point table.
0
Hexadecimal data
Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Dwell write type
0: Valid after write
1: Valid when power is switched on again after write
0
0
(f) Auxiliary function
Read the auxiliary function of the point table.
1) Transmission
Transmit command [6][4] and any of data No. [0][1] to [F][F] corresponding to the point table to be
read. Refer to section 15.4.1.
2) Reply
The slave station sends back the auxiliary function of the requested point table.
0
Hexadecimal data
Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Auxiliary function write type
0: Valid after write
1: Valid when power is switched on again after write
0
0