4 - 13
4. SIGNALS AND WIRING
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the sheath has been stripped, the cable can be used as it is.
7mm
Sheath
Core
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
Bar terminal type
[mm
2
]
AWG
For 1 cable
For 2 cables
Crimping tool
Maker
1.25/1.5 16 AI1.5-8BK
AI-TWIN2 1.5-8BK
2.0/2.5 14 AI2.5-8BU
AI-TWIN2 2.5-10BU
CRIMPFOX-ZA3 Phoenix
Contact
2) CNP2
CNP2 is the same as MR-J3-100T or smaller capacities. Refer to (1) (b) of this section.
(c) As twin type connector for CNP2 (L
11
, L
21
) is the same as MR-J3-100T or smaller.
Refer to (1) (C) of this section.
Summary of Contents for MELSERVO MR-J3-xT