14 - 47
14. OPTIONS AND AUXILIARY EQUIPMENT
Use wires 8) of the following sizes with the brake unit (FR-BU) and power regeneration converter (FR-RC).
Model Wires[mm
2
]
FR-BU-15K 3.5(AWG12)
FR-BU-30K 5.5(AWG10)
FR-BU-55K 14(AWG6)
FR-RC-15K 14(AWG6)
FR-RC-30K 14(AWG6)
FR-RC-55K 22(AWG4)
Table 14.2 Recommended crimping terminals
Servo amplifier side crimping terminals
Servo amplifier side crimping terminals
Symbol Crimping
terminal
Applicable tool
Maker name
Symbol Crimping
terminal
Applicable tool
Maker name
Body YPT-60-21
Dice TD-124 TD-112
a 32968
59239
Tyco
Electronics
(Note
1 2)
e
38-S6
Body YF-1 E-4
Head YET-60-1
Dice TD-124 TD-112
Japan
Solderless
Terminal
b FVD8-5
Body YF-1 E-4
Head YNE-38
Dice DH-111 DH-121
R38-6S
NOP60
NOM60
NICHIFU
c FVD14-6
Body YF-1 E-4
Head YNE-38
Dice DH-112 DH-122
Japan
Solderless
Terminal
Body YDT-60-21
Dice TD-125 TD-113
d FVD22-6
Body YF-1 E-4
Head YNE-38
Dice DH-113 DH-123
f
(Note 1)
R60-8
Body YF-1 E-4
Head YET-60-1
Dice TD-125 TD-113
Japan
Solderless
Terminal
Note 1. Coat the part of crimping with the insulation tube.
2. Some crimping terminals may not be mounted depending on the size. Make sure to use the recommended ones.