5 - 37
5. STARTUP
5.6.5 Stopper type home position return
In stopper type home position return, a machine part is pressed against a stopper or the like by jog operation to
make a home position return and that position is defined as a home position.
(1) Signals, parameters
Set the input devices and parameters as follows:
Item Device/Parameter
used
Description
Automatic/manual selection (RYn6)
Turn RYn6 ON.
Manual home position return
mode selection
Point table No. selection 1 to 8
(RYnA to RYnE, RY(n+2)3 to RY(n+2)5)
RYnA to RYnE, RY(n+2)3 to RY(n+2)5 are turned
off.
Stopper type home position
return
Parameter No.PC02
3 : Stopper type home position return is
selected.
Home position return direction Parameter No.PC03
Refer to section 5.6.1 (2) and choose the home
position return direction.
Home position return speed
Parameter No.PC04
Set the speed till contact with the stopper.
Stopper time
Parameter No.PC09
Time from when the part makes contact with the
stopper to when home position return data is
obtained to output home position return
completion (ZP).
Stopper type home position
return torque limit
Parameter No.PC10
Set the servo motor torque limit value for
execution of stopper type home position return.
Home position return
acceleration time constant
Point table No.1
Use the acceleration time constant of point table
No.1.
Home position return position
data
Parameter No.PC07
Set the current position at home position return
completion.
Summary of Contents for MELSERVO MR-J3-xT
Page 22: ...8 MEMO ...
Page 156: ...4 46 4 SIGNALS AND WIRING MEMO ...
Page 276: ...7 26 7 MR Configurator MEMO ...
Page 324: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 418: ...14 66 14 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...