1 - 27
1. FUNCTIONS AND CONFIGURATION
1.8 Selection of operation method
Using the CC-Link communication functions, this servo enables a wide variety of operation methods. The
operation method changes depending on the input signal, parameter and point table setting.
The flow of the operation method that changes depending on the signal and parameter setting status is shown
in the chart for your reference.
MR-J3-T occupied
station count setting
switch SW1
Remote register-based
point table No. setting
auxiliary function invalid
OFF
ON
2 stations
occupied
Parameter No. PA30
Remote register-based
position data setting/point
table No. (speed) setting
auxiliary function invalid
Remote register-based
position data/speed data
setting auxiliary function
invalid
Remote input-based point
table No. setting auxiliary
function valid
(Refer to section 5.4)
1 station
occupied
OFF OFF
Servo amplifier
MR-J3-T
OFF ON
(Refer to section 3.2.5)
Remote input position/speed
specifying system selection
(RY(n+2)A)
0
1
2