14 - 1
14. OPTIONS AND AUXILIARY EQUIPMENT
14. OPTIONS AND AUXILIARY EQUIPMENT
WARNING
Before connecting any option or auxiliary equipment, make sure that the charge
lamp is off more than 15 minutes after power-off, then confirm the voltage with a
tester or the like. Otherwise, you may get an electric shock.
CAUTION
Use the specified auxiliary equipment and options. Unspecified ones may lead to a
fault or fire.
14.1 Cable/connector sets
As the cables and connectors used with this servo, purchase the options indicated in this section.
14.1.1 Combinations of cable/connector sets
Serevo
motor
HF-MP
HF-KP
15) 16) 17) 18)
19) 20)
3) 4) 5) 6)
7) 8)
13) 14)
9) 10) 11) 12)
CN5
CN1
CN6
CN2
CN3
CNP1
CNP2
CNP3
CN4
Direct connection type (cable length 10m or less, IP65)
Junction type (cable length more than 10m, IP20)
To 24VDC power
supply for
electromagnetic
brake
Battery unit
MR-J3BAT
Encoder
connector
Brake
connector
Power supply
connector
To next page b)
To next page a)
Note. Connectors for 3.5kw or less. For 5kw or more, terminal blocks.
32)
Personal computer
Servo amplifier
1) 2)
33)
Note
21) 22)
23)
31)
Summary of Contents for MELSERVO MR-J3-xT
Page 22: ...8 MEMO ...
Page 156: ...4 46 4 SIGNALS AND WIRING MEMO ...
Page 276: ...7 26 7 MR Configurator MEMO ...
Page 324: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 418: ...14 66 14 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...