10 - 2
10. SPECIAL ADJUSTMENT FUNCTIONS
(2) Parameters
The operation of adaptive tuning mode (parameter No. PB01).
Filter tuning mode selection
0 0 0
Parameter No.60
Setting Filter adjustment mode Automatically set parameter
0 Filter
OFF
(Note)
1
Filter tuning mode
Parameter No. PB13
Parameter No. PB14
2 Manual
mode
Note. Parameter No. PB19 and PB20 are fixed to the initial values.