3 - 11
3. CC-LINK COMMUNICATION FUNCTIONS
PLC
Servo amplifier (RWwn)
Servo amplifier
PLC (RWrn)
(Note 1)
Address No.
Signal name
(Note 1)
Address No.
Signal name
RWwn
(Note 2) Monitor 1
RWrn
Monitor 1 data under 16 bit
RWwn+1
(Note 2) Monitor 2
RWrn+1
Monitor 1 data upper 16 bit
RWwn+2 Instruction
code
RWrn+2 Answer
code
RWwn+3
Writing data
RWrn+3
Read the data
RWwn+4
(Note 3) Position command data under 16 bit/Point table
No.
RWrn+4
RWwn+5
Position command data upper 16 bit
RWrn+5
Monitor 2 data under 16 bit
RWwn+6
(Note 4) Speed command data/Point table No.
RWrn+6
Monitor 2 data upper 16 bit
RWwn+7 Reserved
RWrn+7 Reserved
Note 1. "n" depends on the station number setting.
2. Specify the code of the under 16 bit as the monitor code of 32-bit data.
3. When the parameter No. PC30 setting is "
0", specify the point table No. in RWwn+4. When the parameter No. PC30
setting is "
1" or "
2", specify the position data in RWwn+4/RWwn+5 and turn ON Position instruction execution
demand (RY(n+2)0).
4. When the parameter No. PC30 setting is "
1", specify the point table No. in RWwn+6. When the parameter No. PC30
setting is "
2", specify the speed data in RWwn+6, and turn ON Speed instruction execution demand (RY(n+2)1). When
the parameter No. PC30 setting is "
0", the RWwn+6 value is not used.