3 - 56
3. CC-LINK COMMUNICATION FUNCTIONS
Sets monitor code (H0016) of motor speed
to RW
W0
.
Turns on monitor output execution demand
(RY08).
Reads RW
R0
or RW
R1
of buffer memory to
D120, D121 when monitoring (RX08) turns on.
CIRCUIT END
Positioning start
command
In position Rough
match
Home position return
completion
Writes position command data (K50000) to
RW
W4
, RW
W5
, and speed data (K100) to
RW
W6
.
Turns on position instruction demand (RY20).
Reads RWR2 to D2 when position instruction
execution completion (RX20) and speed
instruction execution completion (RX21) turn on.
Turns on speed instruction demand (RY21).
Command request time 10ms
Turns off position instruction demand (RY20).
Turns off speed instruction demand (RY21).
Positioning start command
Forward rotation start (RY01)
Reverse rotation start (RY02)
Positioning start command reset
Writes M100 to M163 to remote output
(RY00 to RY3F) of buffer memory.