5 - 41
5. STARTUP
(2) Timing chart
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0
Automatic/manual selection
(RYn6)
Movement finish (RXnC)
Rough match (RXn2)
Home position return
completion (ZP)
Servo motor speed
Proximity dog (DOG)
Forward rotation start (RYn1)
Home position return speed
Creep speed
Moving distance after proximity dog
Home position shift distance
6ms or more
3ms or less
Home position address
Parameter No. PC07
Reverse rotation start (RYn2)
Selected point table No.
Proximity dog
Forward
rotation
0r/min
The parameter No.PC17 (home position return position data) setting value is the positioning address after