14 - 33
14. OPTIONS AND AUXILIARY EQUIPMENT
14.5 Power regeneration common converter
POINT
For details of the power regeneration common converter FR-CV, refer to the
FR-CV Installation Guide (IB(NA)0600075).
Do not supply power to the main circuit power supply terminals (L
1
, L
2
, L
3
) of
the servo amplifier. Doing so will fail the servo amplifier and FR-CV.
Connect the DC power supply between the FR-CV and servo amplifier with
correct polarity. Connection with incorrect polarity will fail the FR-CV and
servo amplifier.
Two or more FR-CV's cannot be installed to improve regeneration capability.
Two or more FR-CV's cannot be connected to the same DC power supply
line.
When using the power regeneration common converter, set parameter No. PA02 to " 01".
(1) Model
Applicable servo amplifier capacity [kW]
(2) Selection
The power regenerative common converter FR-CV can be used for the servo amplifier of 200VAC class
with 750W to 22kW. The following shows the restrictions on using the FR-CV.
(a) Up to six servo amplifiers can be connected to one FR-CV.
(b) FR-CV capacity [W] Total of rated capacities [W] of servo amplifiers connected to FR-CV2.
(c) The total of used servo motor rated currents should be equal to or less than the applicable current [A] of
the FR-CV.
(d) Among the servo amplifiers connected to the FR-CV, the servo amplifier of the maximum capacity
should be equal to or less than the maximum connectable capacity [W].
The following table lists the restrictions.
FR-CV-
Item
7.5K 11K 15K 22K 30K 37K 55K
Maximum number of connected servo amplifiers
6
Total of connectable servo amplifier capacities [kW]
3.75
5.5
7.5
11
15
18.5
27.5
Total of connectable servo motor rated currents [A]
33
46
61
90
115
145
215
Maximum servo amplifier capacity [kW]
3.5
5
7
11
15
15
22
When using the FR-CV, always install the dedicated stand-alone reactor (FR-CVL (-H)).
Power regeneration common converter
Dedicated stand-alone reactor
FR-CV-7.5K (-AT)
FR-CVL-7.5K
FR-CV-11 K (-AT)
FR-CVL-11 K
FR-CV-15K (-AT)
FR-CVL-15K
FR-CV-22K (-AT)
FR-CVL-22K
FR-CV-30K (-AT)
FR-CVL-30K
FR-CV-37K FR-CVL-37K