10 - 12
10. SPECIAL ADJUSTMENT FUNCTIONS
10.6.3 Parameters
When using the gain changing function, always set " 3" in parameter No. PA08 (auto tuning) to choose
the manual mode of the gain adjustment modes. The gain changing function cannot be used in the auto tuning
mode.
Parameter
No.
Abbrevi
ation
Name Unit
Description
PB06 GD2
Ratio of load inertia moment to servo
motor inertia moment
times
Control parameters before changing
PB07
PG1
Model loop gain
rad/s
Position and speed gains of a model used to set the response
level to a command. Always valid.
PB08 PG2
Position
loop
gain
rad/s
PB09
VG2
Speed loop gain
rad/s
PB10
VIC
Speed integral compensation
ms
PB29 GD2B
Gain changing ratio of load inertia
moment to servo motor inertia
moment
times
Used to set the ratio of load inertia moment to servo motor
inertia moment after changing.
PB30
PG2B Gain changing position loop gain 2
rad/s Used to set the value of the after-changing position loop gain 2.
PB31
VG2B Gain changing speed loop gain 2
rad/s Used to set the value of the after-changing speed loop gain.
PB32 VICB
Gain changing speed integral
compensation
ms
Used to set the value of the after-changing speed integral
compensation.
PB26
CDP
Gain changing selection
Used to select the changing condition.
PB27
CDS
Gain changing condition
kpps
pulse
r/min
Used to set the changing condition values.
PB28
CDT
Gain changing time constant
ms
You can set the filter time constant for a gain change at
changing.
PB33 VRF1B
Gain changing vibration suppression
control vibration frequency setting
Hz
Used to set the value of the after-changing vibration suppression
control vibration frequency setting.
PB34 VRF2B
Gain changing vibration suppression
control resonance frequency setting
Hz
Used to set the value of the after-changing vibration suppression
control resonance frequency setting.