6 - 30
6. PARAMETERS
No. Symbol
Name and Function
Initial
value
Unit
Setting
range
PD03
*DIA3 Input signal automatic ON selection 3
Select the input devices to be automatically turned ON.
part is for manufacturer setting. Do not set the value by any means.
0
Initial value
BIN
HEX
Signal name
0
Automatic/manual
selection (MD0)
0
0
0
0 0 0
BIN 0: Used in CC-Link or as external
input signal.
BIN 1: Automatic ON
0000h Refer
to
Name and
function
column.
PD04
*DIA4 Input signal automatic ON selection 4
Select the input devices to be automatically turned ON.
part is for manufacturer setting. Do not set the value by any means.
0
0
Initial value
BIN
HEX
Signal name
Point table No.
selection 2 (DI1)
0
BIN 0: Used in CC-Link or as external
input signal.
BIN 1: Automatic ON
0
0
Point table No.
selection 1 (DI0)
Point table No.
selection 3 (DI2)
Point table No.
selection 4 (DI3)
0
0
Initial value
BIN
HEX
Signal name
Point table No.
selection 6 (DI5)
0
0
0
Point table No.
selection 5 (DI4)
Point table No.
selection 7 (DI6)
Point table No.
selection 8 (DI7)
0 0
0000h Refer
to
Name and
function
column.
PD05
For manufacturer setting
Do not change this value by any means.
0000h