4 - 20
4. SIGNALS AND WIRING
(1) Input device
POINT
Input devices assigned to the CN6 connector pins cannot be used with the
remote input of the CC-Link communication function.
Device Symbol
Connector
pin No.
Functions/Applications
Forced stop
EMG
CN6-1
Forced stop (EMG) is fixed at CN6-1. Assigning this device to any other pin is
not allowed. For device details, refer to section 3.5.1 (1).
Servo-on
SON
For device details, refer to section 3.5.1 (1).
Forward rotation start
ST1
Reverse rotation start
ST2
Proximity dog
DOG
CN6-2
(Note)
Forward rotation stroke end
LSP
CN6-3
(Note)
Reverse rotation stroke end
LSN
CN6-4
(Note)
Automatic/manual selection
MD0
Temporary stop/Restart
TSTP
Internal torque limit
selection
TL1
Proportion control
PC
Gain switch
CDP
Reset RES
Clear CR
Turn CR on to clear the position control counter droop pulses on its leading
edge. The pulse width should be 10ms or more.
When the parameter No. PD22 setting is " 1", the pulses are always
cleared while CR is on.
Manual pulse generator
multiplication 1
TP0
Used to select the multiplication factor of the manual pulse generator.
When it is not selected, the parameter No. PA05 setting is made valid.
Manual pulse generator
multiplication 2
TP1
(Note)
Input
signal
TP1
TP0
Manual pulse generator
multiplication factor
0
0
Parameter No. PA05 setting
0
1
1
time
1
0
10
times
1
1
100
times
Note. 0: OFF
1: ON
Note. These are pin Nos. assigned at default.