3 - 43
3. CC-LINK COMMUNICATION FUNCTIONS
3.7.4 Reading the data
Read various data of the servo amplifier.
(1) Reading the monitor value
Read the (feedback pulse value) of the servo amplifier of station 2 to D1.
Data No.
Description
H000A
Cumulative feedback pulse data (hexadecimal)
The answer code at instruction code execution is set to D9.
Outputs M0 for normal reply.
Sets monitor code (H000A) of feedback
pulse value to RW
W4
, RW
W5
.
Turns on Monitor output execution
demand (RY28).
Reads data to RW
R4
and RW
R5
of buffer
memory when answer code is normal reply.
Monitor stop
Read
setting
Reads remote input (RX20 to RX5F)
of buffer memory to M200 to M263.
Stores answer code to D9.
Writes M100 to M131 to remote output
(RY20 to RY5F) of buffer memory.
Summary of Contents for MELSERVO MR-J3-xT
Page 22: ...8 MEMO ...
Page 156: ...4 46 4 SIGNALS AND WIRING MEMO ...
Page 276: ...7 26 7 MR Configurator MEMO ...
Page 324: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 418: ...14 66 14 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...