Parameters
(M) Monitor display and monitor output signal
FR-F800
5 - 231
5.8.6 Output
terminal
function selection
Use the following parameters to change the functions of the open collector output terminals, relay
output terminals, or virtual terminals of CC-Link IE Field Network Basic (for FR-F800-E).
The initial value is for standard models.
The initial value is for separated converter types.
The setting is available for FR-F800-E only.
The parameter is used when the CC-Link IE Field Network Basic is selected (for FR-F800-E).
(Refer to page 5-618.)
Parameters referred to
Pr. 3
Base frequency
=>
Pr. 52
Operation panel main monitor selection
=>
Pr. 54
FM/CA terminal function selection
=>
Pr. 158
AM terminal function selection
=>
Pr.
Name
Initial
value
Initial set signal
Setting range
190
M400
RUN terminal function
selection
Open
collector
output
terminal
0
RUN (Inverter running)
0 to 5, 7, 8, 10 to 19, 25, 26, 35,
39 to 42, 45 to 54, 57, 64 to 68,
70 to 80, 82, 85, 90 to 96, 98 to 105,
107, 108, 110 to 116, 125, 126, 135,
139 to 142, 145 to 154, 157,
164 to 168, 170 to 180, 182, 185,
190 to 196, 198 to 208, 211 to 213,
215, 217 to 220, 226, 228 to 230,
242
, 300 to 308, 311 to 313, 315,
317 to 320, 326, 328 to 330, 342
191
M401
SU terminal function
selection
1
SU (Up to frequency)
192
M402
IPF terminal function
selection
IPF (Instantaneous
power failure/
undervoltage)
9999
193
M403
OL terminal function
selection
3
OL (Overload warning)
194
M404
FU terminal function
selection
4
FU (Output frequency
detection)
195
M405
ABC1 terminal function
selection
Relay
output
terminal
99
ALM (Fault)
0 to 5, 7, 8, 10 to 19, 25, 26, 35,
39 to 42, 45 to 54, 57, 64 to 68,
70 to 80, 82, 85, 90, 91, 94 to 96,
98 to 105, 107, 108, 110 to 116, 125,
126, 135, 139 to 142, 145 to 154,
157, 164 to 168, 170 to 180, 182,
185, 190, 191, 194 to 196,
198 to 208, 211 to 213, 215,
217 to 220, 226, 228 to 230, 242
,
300 to 308, 311 to 313, 315,
317 to 320, 326, 328 to 330, 342
196
M406
ABC2 terminal function
selection
9999
No function
313
M410
DO0 output selection
Option
terminal
9999
No function
0 to 5, 7, 8, 10 to 19, 25, 26, 35,
39 to 42, 45 to 54, 57, 64 to 66, 68,
70 to 80, 85 to 96, 98 to 105, 107,
108, 110 to 116, 125, 126, 135,
139 to 142, 145 to 154, 157,
164 to 166, 168, 170 to 180,
185 to 196, 198 to 208, 211 to 213,
215, 217 to 220, 226, 228 to 230,
242, 300 to 308, 311 to 313, 315,
317 to 320, 326, 328 to 330, 342,
9999
314
M411
DO1 output selection
9999
315
M412
DO2 output selection
9999
Pr.
Name
Initial
value
Setting range
Description
289
M431
Inverter output terminal
filter
9999
5 to 50 ms
Set the time delay for the output terminal
response.
9999
No output terminal filter.
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......