Parameter List
Parameters
5 - 6
Ad
ju
st
a
b
le
5
p
o
in
ts
V
/F
100
G040
V/F1 (first frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
101
G041
V/F1 (first frequency voltage)
0 to 1000 V
0.1 V
0 V
102
G042
V/F2 (second frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
103
G043
V/F2 (second frequency voltage)
0 to 1000 V
0.1 V
0 V
104
G044
V/F3 (third frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
105
G045
V/F3 (third frequency voltage)
0 to 1000 V
0.1 V
0 V
106
G046
V/F4 (fourth frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
107
G047
V/F4 (fourth frequency voltage)
0 to 1000 V
0.1 V
0 V
108
G048
V/F5 (fifth frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
109
G049
V/F5 (fifth frequency voltage)
0 to 1000 V
0.1 V
0 V
⎯
111
F031
Check valve deceleration time
0 to 3600 s, 9999
0.1 s
9999
P
U
con
n
e
ct
or
comm
un
ic
ation
117
N020
PU communication station number
0 to 31
1
0
118
N021
PU communication speed
48, 96, 192, 384, 576,
768, 1152
1
192
119
⎯
PU communication stop bit length /
data length
0, 1, 10, 11
1
1
N022
PU communication data length
0, 1
0
N023
PU communication stop bit length
0, 1
1
120
N024
PU communication parity check
0 to 2
1
2
121
N025
Number of PU communication retries
0 to 10, 9999
1
1
122
N026
PU communication check time interval
0, 0.1 to 999.8 s, 9999
0.1 s
9999
123
N027
PU communication waiting time
setting
0 to 150 ms, 9999
1
9999
124
N028
PU communication CR/LF selection
0, 1, 2
1
1
⎯
125
T022
Terminal 2 frequency setting gain
frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
⎯
126
T042
Terminal 4 frequency setting gain
frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
PI
D
o
p
e
rat
io
n
127
A612
PID control automatic switchover
frequency
0 to 590 Hz, 9999
0.01 Hz
9999
128
A610
PID action selection
0, 10, 11, 20, 21, 50, 51,
60, 61, 70, 71, 80, 81, 90,
91, 100, 101, 1000, 1001,
1010, 1011, 2000, 2001,
2010, 2011
1
0
129
A613
PID proportional band
0.1 to 1000%, 9999
0.1%
100%
130
A614
PID integral time
0.1 to 3600 s, 9999
0.1 s
1 s
131
A601
PID upper limit
0 to 100%, 9999
0.1%
9999
132
A602
PID lower limit
0 to 100%, 9999
0.1%
9999
133
A611
PID action set point
0 to 100%, 9999
0.01%
9999
134
A615
PID differential time
0.01 to 10 s, 9999
0.01 s
9999
Bypa
ss
135
A000
Electronic bypass sequence selection
0, 1
1
0
136
A001
MC switchover interlock time
0 to 100 s
0.1 s
1 s
137
A002
Start waiting time
0 to 100 s
0.1 s
0.5 s
138
A003
Bypass selection at a fault
0, 1
1
0
139
A004
Automatic switchover frequency from
inverter to bypass operation
0 to 60 Hz, 9999
0.01 Hz
9999
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (5)
Simple
Simple
Simple
Simple
Simple
Simple
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......