Parameters
Parameter List
FR-F800
5 - 7
Back
lash
me
as
ur
e
s
140
F200
Backlash acceleration stopping
frequency
0 to 590 Hz
0.01 Hz
1 Hz
141
F201
Backlash acceleration stopping time
0 to 360 s
0.1 s
0.5 s
142
F202
Backlash deceleration stopping
frequency
0 to 590 Hz
0.01 Hz
1 Hz
143
F203
Backlash deceleration stopping time
0 to 360 s
0.1 s
0.5 s
⎯
144
M002
Speed setting switchover
0, 2, 4, 6, 8, 10, 12, 102,
104, 106, 108, 110, 112
1
4
PU
145
E103
PU display language selection
0 to 7
1
—
⎯
147
F022
Acceleration/deceleration time
switching frequency
0 to 590 Hz, 9999
0.01 Hz
9999
C
u
rr
en
t detec
tion
148
H620
Stall prevention level at 0 V input
0 to 400%
0.1%
120%
110%
149
H621
Stall prevention level at 10 V input
0 to 400%
0.1%
150%
120%
150
M460
Output current detection level
0 to 400%
0.1%
120%
110%
151
M461
Output current detection signal delay
time
0 to 10 s
0.1 s
0 s
152
M462
Zero current detection level
0 to 400%
0.1%
5%
153
M463
Zero current detection time
0 to 10 s
0.01 s
0.5 s
⎯
154
H631
Voltage reduction selection during stall
prevention operation
0, 1, 10, 11
1
1
⎯
155
T730
RT signal function validity condition
selection
0, 10
1
0
⎯
156
H501
Stall prevention operation selection
0 to 31, 100, 101
1
0
⎯
157
M430
OL signal output timer
0 to 25 s, 9999
0.1 s
0 s
⎯
158
M301
AM terminal function selection
1 to 3, 5 to 14, 17, 18, 21,
24, 34, 50, 52 to 54, 61,
62, 67, 69, 70, 86 to 96, 98
1
1
⎯
159
A005
Automatic switchover frequency range
from bypass to inverter operation
0 to 10 Hz, 9999
0.01 Hz
9999
⎯
160
E440
User group read selection
0, 1, 9999
1
9999
0
⎯
161
E200
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
A
u
to
matic r
e
star
t
func
tions
162
A700
Automatic restart after instantaneous
power failure selection
0 to 3, 10 to 13
1
0
163
A704
First cushion time for restart
0 to 20 s
0.1 s
0 s
164
A705
First cushion voltage for restart
0 to 100%
0.1%
0%
165
A710
Stall prevention operation level for
restart
0 to 400%
0.1%
120%
110%
Cu
rr
e
n
t
det
e
ctio
n
166
M433
Output current detection signal
retention time
0 to 10 s, 9999
0.1 s
0.1 s
167
M464
Output current detection operation
selection
0, 1, 10, 11
1
0
⎯
168
E000
Parameter for manufacturer setting. Do not set.
E080
⎯
169
E001
E081
Cu
m
u
la
ti
ve
mo
n
it
o
r clear
170
M020
Watt-hour meter clear
0, 10, 9999
1
9999
171
M030
Operation hour meter clear
0, 9999
1
9999
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (6)
Simple
Simple
Simple
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......