Command source switchover via external terminals (X67)
●
In the Network operation mode, the start command source and speed command source can be
switched over by the command source switchover signal (X67). This can be used to control signal
inputs from both the external terminals and via communication.
●
For the X67 signal, set "67" to any of Pr. 178 to Pr. 189 (input terminal function selection) to assign
the function to a control terminal.
●
When the X67 signal is OFF, the start command source and speed command source are given via
control terminals.
5.6.4
Reverse rotation prevention selection
This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
●
Set this parameter to limit the motor rotation to only one direction.
●
This parameter is valid for all of the reverse rotation and forward rotation keys of the operation
panel and of the parameter unit, the start signals (STF, STR signals) via external terminals, and the
forward and reverse rotation commands through communication.
X67 signal state
Start command source
Speed command source
Signal not assigned
According to Pr. 338
According to Pr. 339
ON
OFF
Commands from external terminals are only valid.
Tab. 5-62:
Switching of command source by the signal X67
NOTES
The ON/OFF state of the X67 signal is applied only during a stop. When the terminals are switched
during operation, the ON/OFF state is applied after a stop.
When the X67 is OFF, a reset via communication is disabled.
Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may
affect the other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 28
Multi-speed input compensation selection
=>
Pr. 59
Remote function selection
=>
Pr. 79
Operation mode selection
=>
Pr.
Name
Initial value
Setting range
Description
78
D020
Reverse rotation prevention
selection
0
0
Both forward and reverse rotations
allowed
1
Reverse rotation disabled
2
Forward rotation disabled
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......