Installation and wiring
Main circuit terminals
FR-F800
2 - 39
For the FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower, it is the gauge of a cable
with the continuous maximum permissible temperature of 75 °C (HIV cable (600 V grade heat-
resistant PVC insulated wire), etc.). It assumes a surrounding air temperature of 50 °C or lower and
the wiring distance of 20 m or shorter.
For the FR-F820-03160(75K) or higher, FR-F840-01800(75K) or higher, it is the gauge of the cable
with the continuous maximum permissible temperature of 90 °C or higher. (LMFC (heat resistant
flexible cross-linked polyethylene insulated cable), etc.). It assumes a surrounding air temperature
of 50 °C or lower and in-enclosure wiring.
For all the 200 V class capacities and FR-F840-00930(45K) or lower, it is the gauge of a cable with
the continuous maximum permissible temperature of 75 °C (THHW cable). It assumes a surround-
ing air temperature of 40°C or lower and the wiring distance of 20 m or shorter.
For the FR-F840-01160(55K) or higher, it is the gauge of a cable with the continuous maximum
permissible temperature of 90°C (THHN cable). It assumes a surrounding air temperature of 40 °C
or lower and in-enclosure wiring.
(Selection example for use mainly in the United States.)
For the FR-F820-00770(18.5K) or lower and the FR-F840-00930(45K) or lower, it is the gauge of a
cable with the continuous maximum permissible temperature of 70 °C (PVC cable). It assumes a
surrounding air temperature of 40 °C or lower and the wiring distance of 20 m or shorter.
For the FR-F820-00930(22K) or higher and the FR-F840-01160(55K) or higher, it is the gauge of a
cable with the continuous maximum permissible temperature of 90 °C (XLPE cable). It assumes a
surrounding air temperature of 40 °C or lower and in-enclosure wiring. (Selection example for use
mainly in Europe.)
The terminal screw size indicates the size of terminal screw for R/L1, S/L2, T/L3, U, V, W, P/+, N/–, P1,
and a screw for earthing (grounding).
The screw size for earthing (grounding) of FR-F820-00930(22K) or higher and FR-F840-04320(185K)
or higher is indicated in parentheses.
A screw size for P/+ terminal for option connection of the FR-F840-03250(132K) and FR-F840-
03610(160K) is indicated in parentheses.
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......