Parameters
(H) Protective function parameter
FR-F800
5 - 149
5.7
(H) Protective function parameter
Purpose
Parameter to set
Refer to
page
To protect the motor from overheating
Electronic thermal O/L
relay
P.H000, P.H006,
P.H010, P.H016,
P.H020, P.H021
Pr. 9, Pr. 51, Pr. 561,
Pr. 607, Pr. 608,
Pr.1016
To set the overheat protection
characteristics for the motor
Free thermal O/L relay
setting
P.H001 to P.H005,
P.H011 to P.H015
Pr. 600 to Pr. 604,
Pr. 692 to Pr. 696
To extend the life of the cooling fan
Cooling fan operation
selection
P.H100
Pr. 244
To detect ground fault at start
Ground fault at start
enable/disable
P.H101
Pr. 249
To vary the operating level of the
undervoltage protective function
Undervoltage level
P.H102
Pr. 598
To initiate an inverter protective
function
Fault initiation
P.H103
Pr. 997
To disable the I/O phase loss
protective function
I/O phase loss protection
selection
P.H200, P.H201
Pr. 251, Pr. 872
To restart using the retry function
when the protective function is
activated
Retry operation
P.H300 to P.H303
Pr. 65,
Pr. 67 to Pr. 69
To operate without activating
protective functions in case of
emergency
Emergency drive
P.H320 to P.H324
Pr. 514, Pr. 515,
Pr. 23, Pr. 524,
Pr. 1013
To set the upper and lower limits of the
output frequency
Maximum/minimum
frequency
P.H400 to P.H402
Pr. 1, Pr. 2, Pr. 18
To operate by avoiding resonance
points
Frequency jump
P.H420 to P.H425,
P.H429
Pr. 31 to Pr. 36,
Pr. 552
To limit the output current so that the
inverter protective function does not
activate
Stall prevention
P.H500, P.H501,
P.H600, P.H601,
P.H610, P.H611,
P.H620, P.H621,
P.H631, P.M430,
P.T010, P.T040
Pr. 22, Pr. 23, Pr. 48,
Pr. 49, Pr. 66,
Pr. 148, Pr. 149,
Pr. 154, Pr. 156,
Pr. 157, Pr. 858,
Pr. 868
To monitor for load faults
Load characteristics fault
detection
P.H520 to P.H527,
P.H531 to P.H535
Pr.1480 to Pr.1492
To shut off the output during
acceleration
Overspeed detection level P.H800
Pr. 374
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......