Parameters
(E) Environment setting parameters
FR-F800
5 - 75
Writing parameters during operation (Pr. 77 = "2")
●
These parameters can always be written.
●
The following parameters cannot be written during operation if Pr. 77 = "2". To change the
parameter setting value, stop the operation.
Pr.
Name
Pr.
Name
23
Stall prevention operation level
compensation factor at double speed
454
Number of second motor poles
48
Second stall prevention operation level
455
Second motor excitation current
49
Second stall prevention operation
frequency
456
Rated second motor voltage
60
Energy saving control selection
457
Rated second motor frequency
66
Stall prevention operation reduction
starting frequency
458 to 462
(Second motor constant)
71
Applied motor
463
Second motor auto tuning setting/status
79
Operation mode selection
541
Frequency command sign selection
(CC-Link)
80
Motor capacity
560
Second frequency search gain
81
Number of motor poles
561
PTC thermistor protection level
82
Motor excitation current
570
Multiple rating setting
83
Rated motor voltage
574
Second motor online auto tuning
84
Rated motor frequency
578
Auxiliary motor operation selection
90 to 94
(Motor constant)
579
Motor connection function selection
95
Online auto tuning selection
598
Undervoltage level
96
Auto tuning setting/status
606
Power failure stop external signal input
selection
135 to 139
(Electronic bypass sequence parameter)
660, 661, 662
(Increased magnetic excitation
deceleration)
178 to 196
(Input and output terminal function
selection)
673
SF-PR slip amount adjustment operation
selection
248
Self power management selection
699
Input terminal filter
254
Main circuit power OFF waiting time
702
Maximum motor frequency
261
Power failure stop selection
706, 707, 711,
712, 717, 721,
724, 725
(PM motor tuning)
289
Inverter output terminal filter
738 to 746
(Second PM motor tuning)
291
Pulse train I/O selection
800
Control method selection
298
Frequency search gain
858
Terminal 4 function assignment
313 to 322
(Extended output terminal function
selection)
859
Torque current/Rated PM motor current
329
Digital input unit selection
860
Second motor torque current/
Rated PM motor current
414
PLC function operation selection
868
Terminal 1 function assignment
415
Inverter operation lock mode setting
977
Input voltage mode selection
418
Extension output terminal filter
998
PM parameter initialization
450
Second applied motor
999
Automatic parameter setting
453
Second motor capacity
1002
Lq tuning target current adjustment
coefficient
Tab. 5-29:
Parameters, that cannot be written during operation
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......