Peripheral devices
Installation and wiring
2 - 6
●
400 V class
Assumes the use of an IPM motor MM-EFS/MM-THE4 or a Mitsubishi 4-pole standard motor with
the power supply voltage of 400 V AC 50 Hz.
Select an MCCB according to the power supply capacity.
Install one MCCB per inverter.
For the use in the United States or Canada, provide the appropriate UL and cUL listed fuse or UL489
molded case circuit breaker (MCCB) that is suitable for branch circuit protection. (Refer to the
Installation Guideline.)
Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic
contactor is 500,000 times. When the magnetic contactor is used for emergency stops during
motor driving, the electrical durability is 25 times.
If using an MC for emergency stop during motor driving, select an MC regarding the inverter input
side current as JEM1038-AC-3 class rated current. When using an MC on the inverter output side
for commercial-power supply operation switching using a general-purpose motor, select an MC
regarding the rated motor current as JEM1038-AC-3 class rated current.
Motor
output
[kW]
Applicable inverter
model
Molded case circuit breaker (MCCB)
or
earth leakage circuit breaker (ELB)
(NF, NV type)
Input-side magnetic contactor
Power factor improving (AC or DC)
reactor
Power factor improving (AC or DC)
reactor
Without
With
Without
With
0.75
FR-F840-00023(0.75K)
5A
5A
S-T10
S-T10
1.5
FR-F840-00038(1.5K)
10A
10A
S-T10
S-T10
2.2
FR-F840-00052(2.2K)
10A
10A
S-T10
S-T10
3.7
FR-F840-00083(3.7K)
20A
15A
S-T10
S-T10
5.5
FR-F840-00126(5.5K)
30A
20A
S-T21
S-T12
7.5
FR-F840-00170(7.5K)
30A
30A
S-T21
S-T21
11
FR-F840-00250(11K)
50A
40A
S-T21
S-T21
15
FR-F840-00310(15K)
60A
50A
S-N35
S-T21
18.5
FR-F840-00380(18.5K)
75A
60A
S-N35
S-N35
22
FR-F840-00470(22K)
100A
75A
S-N35
S-N35
30
FR-F840-00620(30K)
125A
100A
S-N50
S-N50
37
FR-F840-00770(37K)
150A
100A
S-N65
S-N50
45
FR-F840-00930(45K)
175A
125A
S-N80
S-N65
55
FR-F840-01160(55K)
200A
150A
S-N80
S-N80
75
FR-F840-01800(75K)
⎯
200A
⎯
S-N95
90
FR-F840-02160(90K)
⎯
225A
⎯
S-N150
110
FR-F840-02600(110K)
⎯
225A
⎯
S-N180
132
FR-F840-03250(132K)
⎯
350A
⎯
S-N220
150
FR-F840-03250(132K)
⎯
350A
⎯
S-N220
160
FR-F840-03610(160K)
⎯
400A
⎯
S-N300
185
FR-F840-04320(185K)
⎯
400A
⎯
S-N300
220
FR-F840-04810(220K)
⎯
500A
⎯
S-N400
250
FR-F840-05470(250K)
⎯
600A
⎯
S-N600
280
FR-F840-06100(280K)
⎯
600A
⎯
S-N600
315
FR-F840-06830(315K)
⎯
700A
⎯
S-N600
Tab. 2-3:
Breakers and contactors (LD rating, 400 V class)
Fig. 2-3:
Installation of the breakers
I002770E
INV
MCCB
INV
MCCB
M
M
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......