Product checking and accessories
Introduction
1 - 4
1.2.2 Accessory
Fan cover fixing screws
These screws are necessary for compliance with the EU Directives.
(Refer to the Installation Guideline.)
Eyebolt for hanging the inverter
1.2.3
How to read the SERIAL number
Rating plate example
The SERIAL consists of one symbol, two characters indicating the production year and month, and six
characters indicating the control number. The last digit of the production year is indicated as the Year,
and the Month is indicated by 1 to 9, X (October), Y (November), or Z (December).
NOTES
The rating plate shows the inverter rated current in SLD operation (Super Light Duty). The over-
load current rating at SLD is 110 % of the rated current for 60 s and 120 % for 3 s at surrounding air
temperature of max. 40 °C.
The inverter model name used in this Instruction Manual consists of the inverter model, and the
applicable motor capacity in brackets specified in [kW], e. g. FR-F820-00046(0.75K). This approach
helps for better understanding and for choosing the right motor. For further specification details
like capacity, current or overload current rating refer to page 8-1.
For selecting the right frequency inverter you should know details of your application and espe-
cially the load characteristic.
Capacity
Screw size (mm)
Quantity
FR-F820-00105(2.2K) to FR-F820-00250(5.5K)
FR-F840-00083(3.7K), FR-F840-00126(5.5K)
M3 × 35
1
FR-F820-00340(7.5K), FR-F820-00490(11K)
FR-F840-00170(7.5K), FR-F840-00250(11K)
M3 × 35
2
FR-F820-00630(15K) to FR-F820-00930(22K)
FR-F840-00310(15K) to FR-F840-00620(30K)
M4 × 40
2
Tab. 1-2:
Fan cover fixing screws
Capacity
Eyebolt size
Quantity
FR-F840-04320(185K) to FR-F840-06830(315K)
M12
2
Tab. 1-3:
Eyebolts for hanging the inverter
Symbol
Year
Month
Control
number
SERIAL
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......