(D) Operation command and frequency command
Parameters
5 - 136
Operation at fault
Selectable with Pr. 75 "Reset selection/disconnected PU detection/PU stop selection"
Selectable with Pr. 122 "PU communication check time interval", Pr. 336 "RS-485 communication
check time interval"
, Pr. 548 "USB communication check time interval", and Pr. 1432 "Ethernet
communication check time interval".
Follows the communication option setting.
In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation
of PU disconnection (E.PUE) follows the Pr. 75 "Reset selection/disconnected PU detection/PU stop
selection" setting.
!
When Pr. 550 "NET mode operation command source selection" = "1" (RS-485 terminals enabled),
or Pr. 550 = "9999" with no communication option connected.
FR-F800-E: When Pr. 550 "NET mode operation command source selection"= "5" (Ethernet connec-
tor enabled), or Pr. 550 = "9999" with no communication option connected.
$
When Pr. 550 "NET mode operation command source selection" = "0" (communication option
enabled), or Pr. 550 "= "9999" with communication option connected.
%
FR-F800-E only
"
FR-F800-E: Not available.
Fault record
Conditions
(Pr. 551 setting)
Operation in each operation mode at error occurrences
PU
operation
External
operation
External/PU
combined
operation
mode 1
(Pr. 79 =3)
External/PU
combined
operation
mode 2
(Pr. 79 =4)
NET
operation
(when
RS-485
terminals
are used)
NET
operation
(when the
Ethernet
connector is
used)
NET
operation
(when
communica-
tion option
is used)
Inverter fault
⎯
Stop
PU connector
disconnection
2 (PU connector)
9999 (automatic
recognition)
Stop/continued
Other than 2
Communication
error at PU
connector
2 (PU connector)
Stop/
continued
Continued
Stop/
continued
Continued
Other than 2
Continued
Communication
error at RS-485
terminals
1 (RS-485
terminals)
Stop/
continued
Continued
Stop/
continued
Continued
—
Continued
Other than 1
Continued
Stop/
continued
—
Continued
Communication
error at USB
connector
3 (USB
connector)
9999 (automatic
recognition)
Stop/
continued
Continued
Other than 3
Continued
Communication
error at Ethernet
board
5
(Ethernet board)
Stop/
continued
Continued
Stop/
continued
—
Continued
Other than 5 or
when the
CC-Link IE Field
Network Basic is
selected
Continued
—
Stop/
continued
Continued
Communication
error at
communication
option
⎯
Continued
Stop/
Tab. 5-60:
Operation at fault
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......